TRL Simulation in Designer Interface
Model Description
Full 3D model of a TRL (Transmit Receive Longitudinal) inspection of a steel pipe with water.
Model Geometry
Parametric Variables
The base CAD model was created in Onshape and allows the following design variables to be adjusted. By default the angle of the cuts on the block and the pipe radius are added as configuration variables for quick access through the Configuration Panel in Onshape.
Parametric Variable | Description | Default Value |
---|---|---|
wedge_ang | Angle of wedge cuts for sensors | 162° |
pipe_rad | Pipe Radius | 152 mm |
block_ang | Angle of main block cut | 15° |
Outputs
Here are a list of the types of outputs to expect from this model:
- Acoustic pressure at nodes along receiver
- Maximum acoustic pressure field
Post Processor Outputs
Runtime Statistics
Model Size | 9411496 elements |
Solve Time | 525 s (8 CPU) |
Core Hours | 0.583 |
Memory Usage | 0.83 GB |
Recommended CPU Configuration | 8 CPU |
CAD Project File
The following input files are required to run this model, click here to download the input files:
The base CAD Model is publicly available to view and copy through Onshape.