Chloe Allison
コメント
-
正式なコメント
Hi there, To answer your questions: 1.The units are decibels per centimetre at damping frequencies in MHz, the MHz is just letting the user know that the damping frequencies must be specified i...
-
正式なコメント
Hi there, You can set the vector to be parallel to the plane surface in the vctr command. However, the wave will not be perfect because it is on a stair stepped surface. You can increase the mesh...
-
正式なコメント
Hi there, You can set the propagation direction of the wave using plod vctr. In this case it would be plod vctr 1 0 0. Because you are loading between two water materials some of the wave will prop...
-
正式なコメント
Hi Nicolas, The information in 'How to apply symmetry' may be slightly misleading, none required really means this is calculated by default. Axisymmetry calculates 1 radian sector of the model so t...
-
正式なコメント
Hi Vigneshwar, Please refer to this article. Best Regards, Chloe
-
正式なコメント
Hi there, Yes that is possible using our debond (modl dbnd) command (see Command Reference for more details). Here is a very simple example of how to set this up. I hope this helps. Best Regard...
-
Hi Jinny, Unfortunately this is happening to some older users also. If you email sales@onscale.com they will get this sorted for you asap. Best Regards, Chloe
-
Hi Lukman, It is hard to comment without being able to see the model but a couple of things to try: Use free boundaries instead of absorbing Place a time history within the tube material and see i...
-
正式なコメント
Hi Lukman, There are a couple of reasons why the tube might not be showing up in the model. Here are some tips to try: Co-ordinate definition is in the wrong order – Primitives are defined using b...
-
正式なコメント
Hi Mohamamd, Have a look at this article. Best Regards, Chloe