Chloe Allison
コメント
-
正式なコメント
Hi there, This methodology should work. Can you share your flxhst file and review file with me via your preffered cloud sharing service and I can take a look for you. Best Regards, Chloe
-
正式なコメント
Hi Christiano, Unfortunately this functionality is not currently available in Designer but here is an example of how to do this in Analyst. https://onscaleus.sharepoint.com/:u:/s/External/ERowVMf...
-
正式なコメント
Hi there, This is strange. When you see this crash could you send the report log to OnScale so we can see what is happening please. A couple of questions to ask: Are you able to run a Designe...
-
正式なコメント
Hi, You can change the data range of the plot using the User defined data range: Designer cannot output pres, this has to be done in Analyst by adding out pres to the data command. Prmx is the s...
-
正式なコメント
Hi Ben, Welcome to the forum! For Analyst: To define pressure waves you need to use the plod command (see Command Reference for more details). You can create pressure waves using different method...
-
Yes you can also add a time shift to load specifically. Click on the load and set the Time Shift in the properties: Best Regards, Chloe
-
No problem. You can add a time delay to your drive function in the properties. You also specify a drive frequency here which drives the piezo crystal at that frequency so you already have that se...
-
正式なコメント
Hi there, I would recommend halving the model to see the cross section or else the model is just water. This will also cut down the estimation time. You can do this by limiting the extents: Be ...
-
正式なコメント
Hi Robin,Just doing a diff check against both input files there a couple of differences that could be causing the issue. The geometry of the plate (xlength = 1 in 3D and 0.7 in 2D, ylength = 0.1 i...
-
Hi Robin, A flxffl is a free field boundary. Take a look at this article. Best Regards, Chloe