Ultrasonic Flow Measurement - 2D

im1.png

Flow Model Execution

Model Description

A 2D model of a pipe with a parabolic flow profile in Y direction across the radius of the pipe. With the flow velocity set in positive X direction, the model can be used to evaluate the effect of flow on the receive signal and severity of beam deflection.

im2.png
Basic Model Schematic

Important: This is not a CFD analysis.  A flow field is loaded in the background and its influence on the acoustic wave is studied.

Parametric Variables

The model allows the following design variables to be adjusted to control design metrics such as maximum flow velocity:

Parametric Variable

Description

Default Value

pipeRad

Radius of the Pipe

20 mm

vflow

Maximum flow velocity in the X-direction

50 m/s

Outputs

Here are a list of the types of outputs to expect from this model:

  • Time Histories (XY Graphs)
    • Drive input signal
    • Receive signal – average pressure across face of receive transducer
  • Field data
    • Maximum Pressure field

im3.png
Post Processor 3D Outputs

Runtime Statistics

Model size

elements

Solve Time

55 s (2 CPU)

Core Hours

0.030

Memory Usage

120MB

Recommended CPU Configuration

2 CPU

Files

The following input files are required to run this model, click here to download the input files:

Download: Pipe Flow 2D